appleton conduit fittings catalog pdf
appleton conduit fittings catalog pdf
1905 W. Haskell St., Appleton, WI 54914 800-558-3414 • www.appletonsupply.com Hip Roof 1. FRIEZE RUNNER- Bottom edge of runner channel must be level and aligned with the bottom
Learn MoreUNILETS® for Use with Threaded Metal Conduit. Catalog Number. Grayloy- U.L. Listed for use with Appleton "Kwiko" and Crouse-Hinds "Chico A" cement.
Learn MoreConduit Body, Type T, FM7, Size: 3/4 Inch, Grayloy Iron., Cat #: APPT27, Mfr: Appleton. Catalog Page - Appleton. Conduit Serve as pulling fittings.
Learn MoreRigid and intermediate metal conduit fittings For ordering purposes, please use GASK in the catalog number (Example: GASK 571).
Learn MoreElectrical Apparatus and Circuits Catalog. 2” Type LB with rollers shown. COMMERCIAL AND INDUSTRIAL FITTINGS: CONDUIT BODIES.
Learn MorePVC is the lightest conduit material and usually the lower cost electrical conduit material. PVC conduits can vary in thickness depending on the uses and where the PVC will be installed. The PVC conduit resists moisture and corrosion. PVC conduit has a higher thermal coefficient of expansion allowing the conduit to expand and contract.
Learn MoreArmored Cable and Flexible Metal Conduit Connectors. Steel Setscrew Connectors and Couplings. Raintight Compression Fittings.
Learn MoreAdd suffix -PVC to catalog number.. FM7™ Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit. NEC/CEC — Suitable for use in the following Hazardous Locations: Class I, Division 2 per NEC 501.10(B)(4) Wet Locations, NEMA 3R with cover and gasket CMMERCIAL AND INDUSTRIAL FITTINGS: CNDUIT BDIES
Learn More762 products Conduit and fittings form systems to route and protect wire and cable. Conduit encases conductors to prevent environmental and impact damage and prevents people from touching wire. Metallic conduit is crush-resistant and intended for heavy-duty applications. PVC conduit is lightweight and suitable for outdoor use.
Learn More877) 803-1478 4 Schedule 40 Conduit Schedule 40 Conduit 10’ Length 20’ Length Part Number Standard Lift Quantity (Ft) Part Number Standard Lift Quantity (Ft) 1” UL10 3,600 UL10-20 7,200 2” UL20 1,400 UL20-20 2,800 3” UL30 880 UL30-20 1,760
Learn More0.14.en.pdf Electrical Connectivity Plugs and receptacles acc. to IEC 60309 from 10A up to 125A. eXLink: easy-to-use 'hot swap' disconnect for electrical apparatus. 0.21.en.pdf Ex-Junction- and Terminal Enclosures Terminal boxes made of moulded plastic, light alloy or stainless steel up to 1026 terminals per enclosure. 0.22.en.pdf Ex-Cable glands
Learn More2" APPLETON FFL200 EMT CONDUIT & FITTINGS EMT CONDUIT & FITTINGS 866-4 .WERNERELECTRIC.COM 6 COMBO FITTINGS EMT to Flex - Set Screw Size (In.) Manufacturer Size (In.)Stock # 100% GTY 1/2" APPLETON3/4"EFC50
Learn MoreIndustrial Conduit Fittings (64) Industrial Conduit Bodies and Boxes (23) Appleton™ JB Conduit Outlet Boxes, Covers and Hangers. Compare Compare Find the right catalog number with our Easy-to-Use Competitor Cross Reference Tool. Emerson. Consider It Solved.™
Learn MorePer NEC 501.15(C)(6), seals in Class I, Division 1 and 2 must be limited to conductor fill of 25% of cross sectional area of a rigid metal conduit of the same trade size unless approved for higher percentage fill. See 40% fill sealing fittings. Turning radius with cover or plug removed. Not UL Listed. CSA Certified only.
Learn MoreDesigned for use indoors or outdoors with rigid conduit and IMC • Ideal for pharmaceutical, chemical and food processing, pulp/paper, nuclear, solar and commercial construction applications
Learn MoreAppleton™ and O-Z/Gedney™ Material Finish Trade Size Configurations Selection Key • Per NEC 250.118(6)(a), the conduit is terminated in listed fittings (i.e. Appleton™ ST and O-Z/Gedney™ 4Q and LM Series) • Per NEC 250.118(6)(b), trade sizes 3/8" and 1/2" contain conductors protected by max 20 amp overcurrent protection
Learn MoreShop for Appleton, Rigid Fittings, Appleton from Platt Electric Supply Sign in to our new website! platt.com (800) 257-5288 Live Chat Feedback Sign In or Register
Learn MoreWhen you need connectors, coupling, locknuts, bushings or straps, you need Bridgeport Rigid and IMC conduit fittings. Features like captive, deep-slot, tri-drive screws, serrated and reversible fully threaded locknuts and smooth and rounded throat openings make Bridgeport products the best choice for unparalleled field performance.
Learn MoreFM9™ Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC. NEC/CEC — Suitable for use in the following Hazardous Locations: Class I, Division 2 per NEC 501.10(B)(4) Wet Locations, NEMA 3R with cover and gasket Appleton ™ FM9 Conduit Bodies Hub Size (Inches) Max. Wire Fill C Max. Wire Fill LB
Learn MoreBridgeport Fittings is a third-generation electrical product manufacturing company. Get to know more about us here. We've got you covered, whether pre or post-sales. Contact our hands-on support team of technicians, electricians and engineers. Call 203-377-5944
Learn MoreSeemlessly retrofits to Crouse- Hinds™ Champ®hoods without an adapter • Three light output levels for retrofit of HID fixtures up to 175 W. • IP68 cord gland sealed wiring inlet to prevent water ingress into fixture from conduit • Rugged housing with superior thermal design translates to long luminaire life. 8
Learn MoreBrowse Products - Commercial Electrical Fittings. Close Explore Emerson Conduit Fittings (48) Service Entry Fittings (14) Commercial Cable and Cord Fittings (11) Conduit Bodies and Boxes (4 Appleton™ Rigid Metal Conduit, IMC or EMT Pipe Hangers. Compare Compare
Learn More1905 W. Haskell St., Appleton, WI 54914 800-558-3414 • www.appletonsupply.com Hip Roof 1. FRIEZE RUNNER- Bottom edge of runner channel must be level and aligned with the bottom surface of the fascia board. Using nailing flange of channel, nail and install along the entire length of the wall surface.
Learn MoreSizes with flat-back design ideal where fitting is mounted flat against surface. Appleton™ Form 85™ Conduit Bodies: Threaded/SetScrew Type ①. Hub Size.
Learn MoreAppleton™ FM7™ Conduit Outlet Bodies are used to connect and change direction of conduit runs. In addition to making bends in a conduit system, they allow connections for branch runs. These conduit bodies serve as pulling fittings and permit access to conductors for splicing and maintenance. Read more Warning
Learn MoreConduit fittings connect conduit to other conduit or to an electrical box. They are available in various metals and with different levels of moisture protection. Products include cast outlet boxes, conduit fittings, and cable sealing fittings for hazardous (classified) locations.
Learn MoreEnclosures, lighting and many conduit fittings get the epoxy powder Detailed lumen information for all globe options available in product catalog pages.
Learn MoreAppleton is a trademark of the. EGS Electrical Group, a joint venture of Emerson and SPX Corp. NOTE: BlueKote is registered for conduit bodies but is not
Learn MoreFlexible Metal Conduit Male Pulling Elbows, ST Connectors, Sealing Gaskets. Application closures and Appleton Sealtite and Cord Grip fittings. For dimensions, see page 45. U.S . Pat 2,782,060 Can. Pat. 507,070 708,255 Catalog Number Size Catalog Number Size "STL" 90° Male Pulling Elbow-Malleable Iron* STL-50 1/2
Learn MoreKwiko®. Cement Req'd. Ozs. (grams). Catalog Number. Almag 35*. Malleable Iron*. Aluminum. 1/2"—3". 1/2"—3". EYS Vertical Conduit Seals. Female. 1/2.
Learn More