General Purpose Motor, 300 HP, 3-Phase, Nameplate RPM 1185, Voltage 460, 449T Frame, CW/CCW Item # 44Z257; Mfr. Model # 449TTDN16077 Full Load Amps 365.0; Frame 449T; Hz 60/50; Motor Service Factor 1.15; Max. Ambient Temp. 40 Degrees C; Motor Thermal Protection None; Ins. Class F;
Learn MoreHow much current does a motor draw? Calculate the amps used by dividing the wattage by the voltage. For example a 500-watt motor — running on 50 volts — will draw 10 amps. A motor with the same wattage — running on 20 volts — will use 25 amps. This is the theoretical number of amps used by the motor. IT IS INTERESTING: Does water get
Learn MoreMechanical: 300 hp, 250 hp, 225 hp. Yamaha's award-winning V6 4.2-liter outboards have been offshore favorites for more than a decade. Initially, boaters were attracted to their power, efficiency and intelligent design. After years of proven performance, our V6 4.2-liters have become known for something perhaps even more valuable offshore
Learn More300 HP Reduced Voltage Electric Motor Soft Starter 361 Amps, 460 Volt, Benshaw/Aucom Part # EMX4i-0580B-V5-C1-H, Built In Bypass And Motor Overload, Made In New Zealand! Three Year Warranty! Voltage: 460. Duty Ratings. Standard Duty(350% for 30 seconds): 400HP 477 Amps. Heavy Duty(450% for 30 seconds): 300HP 361 Amps
Learn MoreUsed 300 HP Horizontal Electric Motor (Toshiba) Used Toshiba 300 HP Electric Motor with following features: • 3580 RPM • 460 Volts • 328 Amps • 3 Phase • 60 Hz • 1.15 Service Factor • TEFC Enclosure • N449TS Frame • TIKK Type • Weight 4,000 lbs • Dims 51"Lx39"Wx31"H. 300 HP. 3580 RPM.
Learn MoreHow to Convert Horsepower to Amps · Amps = (Horsepower × 746) ÷ Efficiency ÷ Volts · Watts = Horsepower × 746 · Watts = Watts / η · Amps = Watts ÷ Volts · Amps = HP
Learn MoreAC current is calculated by the power factor of 0.86 for single-phase supply and 0.8 for three-phase supply. Look at the table the 1 hp motor takes will be 1.3 A at 440 Volts three-phase at
Learn MoreSolution: From single phase AC circuit formula for HP to Amps conversion: I =. 2 * 746 230 * (90/100) * 0.92. =7.834 Amps. Amps to HP conversion: Consider a single phase motor that has the following data: Given: Voltage =230 V.
Learn MoreHP 208 Volts 230 Volts 460 Volts 1/2 2.4 2.2 1.1 3/4 3.5 3.2 1.6 1 4.6 4.2 2.1
Learn MoreFull load amps for single and 3-phase 460 volts, 230 volts and 115 volts electric motors.
Learn MoreConverting HP to Amps: A general step for converting HP to amps for all types of circuit is given as: Step1: converting HP to watts, by multiplying HP with 746. Step2: dividing watts with
Learn MoreIEEE 841 Motor: 300 HP, 1,780 Nameplate RPM, 460V AC, 447/9T Frame, 330.0 Full Load Amps, Ball ; Motor Mounting Type Rigid Base ; Motor Mounting Position
Learn MoreMarathon XRI® General Purpose General Purpose Motors, TEFC, 300 HP, 3 Ph, 60 Hz, 575 V, 1785 RPM, 449T - L472A
Learn MoreMotor No load Calculator: Choose the motor type, then enter the full load current of the motor. Then press the calculate button to motor get no-load current. Also, the motor rated below 3 HP the motor will take up to 40% to 60% of the full load current at the delta connection. Select current type:
Learn MoreHP 115 Volts 200 Volts 208 Volts 230 Volts 460 Volts 575 Volts 2300 Volts For example, if there are three 15-amp motors in the circuit, the ampacity rating of the wire feeding the circuit
Learn More230 volts motor - 3-phase : 2.5 amps/hp; 460 volts motor - 3-phase : 1.25 amps/hp; Always check nameplate information before designing protective devices, wiring and switch gear.
Learn Morerequirements for Motor Branch circuit and Short-Circuit. Protection. Selecting Fuses for Motor Running Protection. Based on Motor Horsepower.
Learn MoreCaution: The actual motor amps may be higher or lower than the average values listed above. For more reliable motor protection, use the actual motor current as listed on the motor
Learn More3 Phase 60 hz Motor Full Load Amps & Locked Rotor Current Estimate --Select HP-- 0.5 hp 0.75 hp 1 hp 1.5 hp 2 hp 3 hp 5 hp 7.5 hp 10 hp 15 hp 20 hp 25 hp 30 hp 40 hp 50 hp 60 hp 75 hp 100 hp 125 hp 150 hp 200 hp 250 hp 300 hp 350 hp 400 hp 450 hp 500 hp --Select Voltage-- 200 VAC 208 VAC 230 VAC 460 VAC 575 VAC 2300 VAC 4000 VAC
Learn MoreInduction motor starting on full voltage (also known as across the line starting or direct on-line starting) has the undesirable effect of drawing five to ten times or more of their full load current. Usually this starting current persists till the motor reaches close to its synchronous speed (rated speed). Induction motors under starting conditions have extremely low power factor of around 10
Learn MoreUsed 300 HP Vertical Electric Motor (US Electric) Used US Electric 300 HP electric motor with following features: • 885 RPM • 4000 Volts • 48 Amps • 3 Phase • 60 Hz • 1.15 Service Factor • 5810P Frame • HV-4 Type • Weight 6,000 lbs • Dims (72"L x 72"W x 96" H) 300 HP. 885 RPM. 3 Phase. 4000 Volts. Stock No: 59225.
Learn MoreDescription. HP. 300 HP Reduced Voltage Starter Panel For Electric Motor (Soft Start),Crusher Duty, 460 Volt, 360 Amps, NEMA 3R Enclosure, Circuit Breaker With Thru Door Disconnect, Dimensions: 48" H x 36" W x 16" D. Weight 325 Lbs. Five Year Warranty!
Learn MoreMotor horsepower: Full load amps 230VAC: 300: 696: 348: These are only intended to be guidelines and in all cases the full load amps of the motor nameplate should be used for final calculations. Motors - AC VFD Drive & 3 Phase Power Training About 90 Marketing April 1, 2017.
Learn MorePremium Efficient Severe Duty Motor, 300 HP, 1200 RPM, 460V, 586/7 Frame, Rigid Base. Model Number: PEWWE300-12-586/7; Full Load Amps. 341. Approximate Weight (lbs) 4136. Color. Gray. Fractional HP Motors; Farm Duty Motors; Premium Efficient Stainless Steel Motors; Open Drip Proof (ODP) Motors
Learn More300 HP Reduced Voltage Electric Motor Soft Starter 361 Amps, 460 Volt, Benshaw/Aucom Part # EMX4i-0580B-V5-C1-H, Built In Bypass And Motor Overload, Made In New Zealand! Three Year Warranty! Voltage: 460. Duty Ratings. Standard Duty(350% for 30 seconds): 400HP 477 Amps. Heavy Duty(450% for 30 seconds): 300HP 361 Amps
Learn MoreCaution: The actual motor amps may be higher or lower than the average values listed above. For more reliable motor protection, use the actual motor current as listed on the motor nameplate. Use this table as a guide only. Horsepower AC Induction Motors Single Phase Three Phase 115 Volt 230 Volt 200 Volt 230 Volt 380-415 Volt 460 Volt 575 Volt
Learn More300 200: 5 4: 220.8 For example, the full-load current of a 5 HP motor at 460V is 7.6 Amps. The breaker must be sized for 7.6 * 1.25 = 10 Amps. Therefore, it is good practice to size the breaker at 15 Amps. A heater is a device that protects a motor from thermal overloads due to excess current in the windings. According to the NEC, the
Learn MoreSpecifications. Horsepower: 300; kW: 220; Service Factor: 1.15; Full Load Amperage @ 2300V: 68.4; Full Load Efficiency @ 2300V: 95; Full Load Amperage
Learn MoreHp to Amps calculation formula, DC, AC, 3 phase, 2 phase, 1 phase: Caution: The actual motor amps may be higher or lower than the average values listed above. For more reliable motor protection, use the actual motor current as listed on the motor nameplate. 100 - 300: 1800: 0.81: 0.88: 0.91: Reference // Power Factor in Electrical
Learn More480V electrical motor wiring data - NEMA amps, starter size, HMCP size for motors ranging 1/2 to 500 hp. Sponsored Links 480 Volt motor wiring data - National Electric Manufacturers Association (NEMA) amps, starter size, motor circuit protection, phase wires, GND and
Learn MoreIts voltage is 220V, while the power factor is 0.8 with an efficiency of 90%. With these values in mind, we'll arrive at the following equation: I = (25 x 746) / (√3 x 220 x 0.8 x 0.9) The total pullout current is 67.98 amperes. 2. Get the exact ampere rating relative to the type of circuit breaker you're using.